Technical Information
|
Pressure (Absolute) and Water Level Measurements MX2001-01-SS-S and MX2001-01-Ti-S
|
Operation Range |
0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude |
Factory Calibrated Range |
69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F) |
Burst Pressure |
310 kPa (45 psia) or 18 m (60 ft) depth |
Water Level Accuracy* |
Typical error: ±0.05% FS, 0.5 cm (0.015 ft) water Maximum error: ±0.1% FS, 1.0 cm (0.03 ft) water |
Raw Pressure Accuracy** |
±0.3% FS, 0.62 kPa (0.09 psi) maximum error |
Resolution |
<0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water |
Pressure Response Time (90%)*** |
<1 second at a stable temperature |
Pressure (Absolute) and Water Level Measurements MX2001-02-SS-S
|
Operating Range |
0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000 m (10,000 ft) of altitude |
Factory Calibrated Range |
69 to 400 kPa (10 to 58 psia), 0° to 40°C (32° to 104°F) |
Burst Pressure |
500 kPa (72.5 psia) or 40.8 m (134 ft) depth |
Water Level Accuracy* |
Typical error: ±0.05% FS, 1.5 cm (0.05 ft) water Maximum error: ±0.1% FS, 3.0 cm (0.1 ft) water |
Raw Pressure Accuracy** |
±0.3% FS, 1.20 kPa (0.17 psi) maximum error |
Resolution |
<0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water |
Pressure Response Time (90%)*** |
<1 second at a stable temperature |
Pressure (Absolute) and Water Level Measurements MX2001-03-SS-S
|
Operation Range |
0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea level, or 0 to 79.5 m (0 to 262 ft) of water at 3,000 m (10,000 ft) of altitude |
Factory Calibrated Range |
69 to 850 kPa (10 to 123.3 psia), 0° to 40°C (32° to 104°F) |
Burst Pressure |
1,200 kPa (174 psia) or 112 m (368 ft) depth |
Water Level Accuracy* |
Typical error: ±0.05% FS, 3.8 cm (0.125 ft) water Maximum error: ±0.1% FS, 7.6 cm (0.25 ft) water |
Raw Pressure Accuracy* |
±0.3% FS, 2.55 kPa (0.37 psi) maximum error |
Resolution |
<0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water |
Pressure Response Time (90)%*** |
<1 second at a stable temperature |
Pressure (Absolute) and Water Level Measurements MX2001-04-SS-S and MX2001-04-Ti-S
|
Operation Range |
0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude |
Factory Calibrated Range |
69 to 145 kPa (10 to 21 psia), 0° to 40°C (32° to 104°F) |
Burst Pressure |
310 kPa (45 psia) or 18 m (60 ft) depth |
Water Level Accuracy* |
Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water |
Raw Pressure Accuracy** |
±0.3% FS, 0.43 kPa (0.063 psi) maximum error |
Resolution |
<0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water |
Pressure Response Time (90)%*** |
<1 second at a stable temperature |
Barometric Pressure (MX2001-TOP)
|
Operation Range |
66 to 107 kPa (9.57 to 15.52 psia) |
Temperature Calibrated Range |
-20 to 50°C (-4 to 122°F) |
Accuracy |
±0.2 kPa (±0.029 psi) over full temperature range at fixed pressure; maximum error ±0.5% FS |
Water Level Accuracy* |
Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water Maximum error: ±0.15% FS, 0.6 cm (0.02 ft) water |
Resolution |
<0.01 kPa (0.0015 psi) |
Response Time |
<1 second at stable temperature |
Stability (Drift) |
<0.01 kPa (0.0015 psi) per year |
Temperature Measurements (All Sensor End Models MX2001-0x-SS-S and MX2001-0x-Ti-S)
|
Operation Range |
-20° to 50°C (-4° to 122°F) |
Accuracy |
±0.44°C from 0° to 50°C (±0.79°F from 32° to 122°F), see Plot A |
Resolution |
0.1°C at 25°C (0.18°F at 77°F), see Plot A |
Response Time (90%) |
5 minutes in water (typical) |
Stability (Drift) |
0.1°C (0.18°F) per year |
Logger
|
Operating Range |
-20° to 50°C (-4° to 122°F) |
Radio Power |
1 mW (0 dBm) |
Transmission Range |
Approximately 30.5 m (100 ft) line-of-sight |
Wireless Data Standard |
Bluetooth Low Energy (Bluetooth Smart®) |
Logging Rate |
1 second to 18 hours |
Logging Modes |
Fixed interval, multiple intervals with up to 8 user-defined logging intervals and durations, or burst |
Memory Modes |
Never Stop (Overwrites Old Data) or Stop When Full |
Start Modes |
On Save (immediate), On Next Interval, On Date/Time |
Stop Modes |
Never Stop (Overwrites Old Data), On Date/Time, After (a specified amount of time), Stop When Memory Fills |
Time Accuracy |
±1 minute per month 0° to 50°C (32° to 122°F) |
Battery |
Two AA, 1.5 V alkaline batteries, user replaceable |
Battery Life |
1 year, typical with logging interval of 1 minute. Faster logging and/or statistics sampling intervals, entering burst logging mode, excessive readouts, checking of Full Status Details, and remaining connected with the app will impact battery life. |
Memory |
256 KB memory (30,000 sets of measurements) |
Full Memory Download Time |
Approximately 2 minutes; may take longer the further the device is from the top end of the logger |
Dimensions |
Top end (MX2001-TOP): 2.54 cm (1.0 inches) diameter, 28.9 cm (11.4 inches) length; mounting hole 7.6 mm (0.3 inches) diameter Sensor end (MX2001-0x-SS-S and MX2001-0x-Ti-S: 2.54 cm (1.0 inches) diameter, 9.91 cm (3.9 inches) length Note: The length of the water level logger cable (CABLE-DR-xxx) can vary -0% to +3% +10 cm (3.9 inches) from the length ordered. The logger adds 38.8 cm (15.3) inches to the length of the cable ordered. |
Weight |
Top end (MX2001-TOP): Approximately 136 g (4.78 oz) in air Stainless sensor end (MX2001-0x-SS-S): Approximately 141.4 g (4.99 oz) in air; approximately 93.4 g (3.3 oz) in fresh water Titanium sensor end (MX2001-0x-Ti-S): Approximately 80 g (2.83 oz) in air; approximately 37 g (1.3 oz) in fresh water |
Wetted Materials |
Top end (MX2001-TOP): PVC housing, Polycarbonate end cap, Viton O-ring Stainless sensor end (MX2001-0x-SS-S): Stainless steel housing, Viton and Buna-N O-rings, ceramic sensor in stainless steel end cap Titanium sensor end (MX2001-0x-Ti-S): Acetal housing, Viton and Buna-N O-rings, ceramic sensor in Titanium end cap Cable (CABLE-DR-XXX): Polycarbonate strain relief (top end connection), PVC end cap (sensor connection), nylon collar nuts, Viton O-rings, polyurethane jacket |
Environmental Rating |
Top end: NEMA 6, IP67; Intermittent 100% RH Sensor end: IP68 |
CE |
The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). |
FC |
See last page of User Manual |