Search
Menu Close

HOBO UX100 - Type J, K, T, E, R, S, B, N Thermocouple Data Logger

Manufacturer:
The HOBO UX100-014M Single Channel Thermocouple data logger records temperature in indoor environments with thermocouple sensors
Part Number: UX100-014M
Back to Previous Page
$376.00 ex GST
i h

Monitor temperatures like a pro with our single-channel thermocouple data logger

A single-channel thermocouple data logger to measure and record temperature in indoor environments. Designed for a broad range of monitoring applications - from industrial process monitoring to concrete maturity testing - this logger provides exceptional flexibility by accepting J, K, T, E, R, S, B or N type thermocouple probes (sold separately). The logger also has an internal 10K thermistor for cold-junction compensation of the thermocouple output. The thermocouple channel has a 20-bit resolution while the internal 10K thermistor has 12-bit resolution. Using HOBOware®, you can easily configure the logger alarm to trip for specific high or low temperatures. Or, you can set up burst logging in which the logger records data at a different interval during certain conditions. The logger can also calculate minimum, maximum, average, and standard deviation statistics. This compact data logger has a built-in LCD screen to monitor temperature, logging status, battery use, and memory consumption in between readouts.

Onset also offers a four-channel thermocouple data logger, the HOBO UX120-014M.



Features

  • High-accuracy J, K, T, E, R, S, B, N thermocouple readings
  • Easy-to-view LCD display
  • Large memory capacity
  • Visual high & low alarm thresholds
  • Burst and Statistics logging modes
  • Record ambient temperature with internal thermistor


Important Information

External sensors sold separately. Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w/HOBOware Pro CD or USB software purchase). See Related Products below.

Technical Information

Thermocouple

Type Range Accuracy Resolution
J -210° to 760°C
(-346° to 1,400°F)
±0.6°C (±1.08°F) ± thermocouple
probe accuracy
0.03°C (0.06°F)
K -260° to 1,370°C
(-436° to 2,498°F)
±0.7°C (±1.26°F) ± thermocouple
probe accuracy
0.04°C (0.07°F)
T -260° to 400°C
(-436° to 752°F)
±0.6°C (±1.08°F) ± thermocouple
probe accuracy
0.02°C (0.03°F)
E -260° to 950°C
(-436° to 1,742°F)
±0.6°C (±1.08°F) ± thermocouple
probe accuracy
0.03°C at (0.05°F)
R -50° to 1,550°C
(-58° to 2,822°F)
±2.2°C (±3.96°F) ± thermocouple
probe accuracy
0.08°C (0.15°F) 
S -50° to 1,720°C
(-58° to 3,128°F)
±2.2°C (±3.96°F) ± thermocouple
probe accuracy
0.08°C (0.15°F)
B 550° to 1,820°C
(1,022° to 3,308°F)
±2.5°C (±4.5°F) ± thermocouple
probe accuracy
0.1°C (0.18F)
N -260° to 1,300°C
(-436° to 2,372°F)
±1.0°C (±1.8°F) ± thermocouple
probe accuracy
0.06°C (0.11°F) 

Internal 10K Thermistor (Temperature) 

Range -20° to 70°C (-4° to 158°F)
Accuracy ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A in User Manual
Resolution 0.024°C at 25°C (0.04°F at 77°F); see Plot A in User Manual
Drift <0.1°C (0.18°F) per year 

Logger

Logger Operating Range Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing);
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Logging Rate 1 second to 18 hours, 12 minutes, 15 seconds
Logging Modes Fixed interval (normal), burst, or statistics
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, or date & time
Restart Mode  Push button
Time Accuracy ±1 minute per month at 25°C (77°F), see Plot B in User Manual
Power Source One 3V CR2032 lithium battery and USB cable
Battery Life 1 year, typical with logging rate of 1 minute and sampling interval of
15 seconds or greater
Memory 512 KB (208,076 measurements, maximum)
Download Type USB 2.0 interface
Full Memory Download Time 1 minute, 30 seconds
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly
or go blank in temperatures outside this range
Size 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight 30 g (1.06 oz) 
Environmental Rating IP50
CE The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).

HOBO Data Logger UX100 series

Learn about this low-cost and accurate temperature, humidity, and thermocouplers data logger series. New logging benefits include minimum, max, average and standard deviation recording, real-time feedback, and faster recording modes. Faster response times and visual alarms are also available. Loggers in this series come with mounting tabs for zip ties, a one-year lithium CR22 battery, and four rare-earth magnets for mounting.

HOBOware Software

HOBOware software is used for launching, reading out, and plotting data from HOBO® data loggers. With HOBOware, you can also check logger status, filter and export data, save changes to graphs in project files, and scale data with the Linear Scaling and Pulse Scaling data assistants. There are two versions of HOBOware: HOBOware and HOBOware Pro.


HOBOware Standard features

  • Simple menus for fast, easy logger setup and readout
  • Point & click for fast setup and readout
  • Scaling to real-world engineering units
  • Presentation-quality graphs
  • Easy export of data files to text or Excel format

FREE DOWNLOAD


Learn more about HOBOware and HOBOware-Pro Features >>


IMPORTANT: This HOBO data logger requires HOBOware software and a communications cable (see related products below)


Monitor temperatures like a pro with our single-channel thermocouple data logger

A single-channel thermocouple data logger to measure and record temperature in indoor environments. Designed for a broad range of monitoring applications - from industrial process monitoring to concrete maturity testing - this logger provides exceptional flexibility by accepting J, K, T, E, R, S, B or N type thermocouple probes (sold separately). The logger also has an internal 10K thermistor for cold-junction compensation of the thermocouple output. The thermocouple channel has a 20-bit resolution while the internal 10K thermistor has 12-bit resolution. Using HOBOware®, you can easily configure the logger alarm to trip for specific high or low temperatures. Or, you can set up burst logging in which the logger records data at a different interval during certain conditions. The logger can also calculate minimum, maximum, average, and standard deviation statistics. This compact data logger has a built-in LCD screen to monitor temperature, logging status, battery use, and memory consumption in between readouts.

Onset also offers a four-channel thermocouple data logger, the HOBO UX120-014M.



Features

  • High-accuracy J, K, T, E, R, S, B, N thermocouple readings
  • Easy-to-view LCD display
  • Large memory capacity
  • Visual high & low alarm thresholds
  • Burst and Statistics logging modes
  • Record ambient temperature with internal thermistor


Important Information

External sensors sold separately. Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w/HOBOware Pro CD or USB software purchase). See Related Products below.