Technical Information
|
Occupancy Sensor
|
Detection range |
maximum 12 m (39.4 ft) |
Detection Performance |
102° (±51°) Horizontal; 92° (±46°) Vertical (see Figure B in User Manual) |
Detection Zones |
92 (see Figure B in User Manual) |
Light Sensor
|
Light Threshold |
> 65 lux |
Light Type |
LED, CFL, fluorescent, HID, incandescent, natural |
Logger
|
Memory Modes |
Wrap when full or stop when full |
Start Modes |
Immediate, push button, date & time, or next interval |
Stop Modes |
When memory full, push button, or date & time |
Time Accuracy |
±1 minute per month at 25°C (77°F) (see Plot A in User Manual) |
Power Source |
One 3V CR2032 lithium battery and USB cable |
Battery Life |
1 year typical use |
Memory |
UX90-005/-006: 128 KB (84,650 measurements, maximum) |
Download Type |
USB 2.0 interface |
Full Memory Download Time |
10 seconds for 128 KB, 30 seconds for 512 KB |
Operating Range |
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing) Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification Occupancy Sensor Range: 20° to 60°C (-4° to 140°F); 15 to 85% RH (non-condensing) |
LCD |
LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range |
Size |
3.66 x 8.48 x 2.87 cm (1.44 x 3.34 x 1.13 in.) |
Weight |
30 g (1.06 oz) |
Environmental Rating |
IP50 |
CE |
The CE Marking identifies this product as complying with all relevant directives in the European Union (EU). |