Technical Information
|
Measurement Specifications
|
Temperature Range |
XSA models: 50°C to 500°C XSB models: 100°C to 500°C
Measurements at lower temperatures are possible with reduced stability
|
Analogue Output Scale |
Factory set to: 4 mA = 0°C 20 mA = 500°C Adjustable via optional touch screen module or RS232 |
Response Time (95%) |
XSA models: 10 ms XSB models: 50 ms Adjustable up to 5 s via averaging function |
Measured Spot Diameter |
From 0.7 mm depending on model and measurement distance (see Field of View Diagrams below) |
Target Sighting |
Red LED built-in as standard on all models, shows the position and size of the measurement area. Switchable on/off. |
Accuracy of Measurement |
XSA models: ± 3°C or 1%, whichever is greater XSB models: ± 5°C |
Repeatability |
XSA models: ± 1°C XSB models: ± 2°C |
Temperature Resolution |
XSA models: 0.5°C XSB models: 1.5°C |
Emissivity Setting |
Adjustable, 0.3 to 1.0, via RS232C or optional touch screen interface |
Electrical Specifications
|
Outputs |
1 analogue output and 1 alarm output |
Analogue Output |
4-20 mA (this is the default factory setting on all models)
Output type can be changed via optional PM030 touch screen interface to a choice of: 0-20 mA mV/°C Voltage (range depends on model)
|
Alarm Output |
1 open drain alarm output, rated 27 V DC, 0.2 A |
Supply Voltage |
5 to 27 V DC, 100 mA max |
Digital Communications |
RS232C Modbus RTU, non-isolated |
Output Cable Connector to Sensor |
XSA models: Connector built into sensor XSB models: Hardwired |
Mechanical Specifications
|
Weight (without cable) |
XSA models: 200 g XSB models: 85 g |
Environmental Specifications (PyroCube Sensor)
|
Environmental Rating |
IP67 |
Operating Ambient Temperature |
0°C to 50°C |
Storage Temperature |
-15°C to 70°C |
Operating Ambient Humidity |
30% to 85% RH non-condensing |