Technical Information
|
Measurement Temperature Range |
0°C to 1000 °C |
Analogue Output |
Selectable 0-5, 1-5 or 0-10 V DC, linear with measured temperature, rescalable via display & controls |
Alarm Output |
Open collector alarm output with adjustable temperature threshold and hysteresis |
Accuracy |
± 1.5% of reading or ± 1.5°C, whichever is greater |
Repeatability |
± 0.5% of reading or ± 0.5°C, whichever is greater |
Emissivity Setting |
Adjustable 0.20 to 1.00 via display & controls |
Response Time |
125 ms |
Spectral Range |
8 to 14 μm |
Supply Voltage (at Sensor) |
24 V DC 6 V DC to 28 V DC (12 V DC minimum if using 0-10 V output) |
Max. Supply Voltage (at Sensor) |
28 V DC |
Min. Supply Voltage (at Sensor) |
6 V DC |
Max. Current Draw |
30 mA |
Max Temperature Span (Linear Output) |
1000°C (full temperature range) |
Min Temperature Span (Linear Output) |
100°C |
Open Collector Alarm Output |
6 to 24 V DC, 50 mA max (see Connections) |
Mechanical
|
Construction |
Black anodised aluminium and blue ABS |
Cable Length |
1 m as standard (longer lengths available to order) |
Weight with 1m Cable |
65 g |
Environmental and Conformity
|
Environmental (IP) Rating |
IP65 |
Ambient (Operating) Temperature Range |
0°C to 70°C |
Ambient (Operating) Humidity |
95% max. non-condensing |
Configuration
|
Configurable Parameters |
• Temperature range (linear output) • Alarm output threshold and hysteresis • Emissivity setting • Reflected temperature |
Temperature Units |
°C / °F |
Signal Processing |
Averaging Period (0.25 to 60 seconds) |
Peak / Valley / Hold |
Hold Period (0.25 to 1200 seconds) |
Electromagnetic Compatibility (EMC) |
EN61326-1, EN61326-2-3 (Electrical Equipment for Measurement, Control and Laboratory Use - EMC Requirements) |
RoHS Compliant |
Yes |