The CO2R-series can measure Carbon Dioxide (Co2) ranges of 400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm
Part Number: CO2R-Series
Manufacturer:
0Types Available
Back to Previous Page
Product Files

Carbon Dioxide (CO2) transmitter CO2R-series have a maintenance-free NDIR sensor

Measuring ranges for Carbon Dioxide (CO2) are 400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm selectable ranges with DIP switch. On request 0-1.000 ppm.

0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc (One output and Two CO2 outputs available).

The estimated operating life for Carbon Dioxide (CO2) transmitter is approx. 15 years.

Featuring ABC functionality – Automatic Baseline Calculation.

Accuracy is 70 ppm +3 % reading.

Power supply 24 Vac/dc.


Options

  • Modbus RS485
  • LCD Display
  • 1 x relay output, can be set individually
  • 2 x relay outputs, can be set individually
  • Buzzer

 

Temperature and Humidity Options

  • Temperature measuring ranges 0 to +50°C or -30 to +70°C
  • Temperature output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
  • Humidity measuring ranges 0 to 100% rH
  • Humidity output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc

 

Ordering examples

CO2R 51 M

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication

CO2R 51 MDR2B

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer

CO2R C1T1H1 MDR2B

  • Carbon Dioxide (CO2) room transmitter with Temperature and Humidity options
  • CO2 output 0-10 Vdc
  • TEMP. output 0-10 Vdc
  • HUM. output 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer


See the datasheet for more information.

Carbon Dioxide (CO2) transmitter CO2R-series have a maintenance-free NDIR sensor

Measuring ranges for Carbon Dioxide (CO2) are 400-2.000 ppm, 0-2.000 ppm, 0-5.000 ppm, 0-10.000 ppm selectable ranges with DIP switch. On request 0-1.000 ppm.

0-10 Vdc, 2-10 Vdc, 4-20 ma, 0-5 Vdc or 1-5 Vdc (One output and Two CO2 outputs available).

The estimated operating life for Carbon Dioxide (CO2) transmitter is approx. 15 years.

Featuring ABC functionality – Automatic Baseline Calculation.

Accuracy is 70 ppm +3 % reading.

Power supply 24 Vac/dc.


Options

  • Modbus RS485
  • LCD Display
  • 1 x relay output, can be set individually
  • 2 x relay outputs, can be set individually
  • Buzzer

 

Temperature and Humidity Options

  • Temperature measuring ranges 0 to +50°C or -30 to +70°C
  • Temperature output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc
  • Humidity measuring ranges 0 to 100% rH
  • Humidity output 0-10 Vdc, 2-10 Vdc, 4-20 mA, 0-5 Vdc or 1-5 Vdc

 

Ordering examples

CO2R 51 M

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication

CO2R 51 MDR2B

  • Carbon Dioxide (CO2) room transmitter
  • Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer

CO2R C1T1H1 MDR2B

  • Carbon Dioxide (CO2) room transmitter with Temperature and Humidity options
  • CO2 output 0-10 Vdc
  • TEMP. output 0-10 Vdc
  • HUM. output 0-10 Vdc
  • Modbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer


See the datasheet for more information.

Picture of VCP CO2R - Carbon Dioxide (CO2) transmitter for room mounting
VCP CO2R - Carbon Dioxide (CO2) transmitter for room mounting
Carbon Dioxide (CO2) transmitter for room mounting, IP41Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 VdcModbus RS485 communication
Part Number: CO2R 51 M
$357.00 ex GST
i h
Delivery date: 4-5 weeks
Picture of VCP CO2R - Carbon Dioxide (CO2) transmitter for room mounting (2 x Relay)
VCP CO2R - Carbon Dioxide (CO2) transmitter for room mounting (2 x Relay)
Carbon Dioxide (CO2) transmitter for room mounting, IP41Two CO2 outputs, Output 1: 4-20 mA and Output 2: 0-10 VdcModbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer
Part Number: CO2R 51 MDR2B
$437.00 ex GST
i h
Delivery date: 4-5 weeks
Picture of VCP CO2R - Carbon Dioxide (CO2) transmitter for room mounting w/- Temperature and Humidity options
VCP CO2R - Carbon Dioxide (CO2) transmitter for room mounting w/- Temperature and Humidity options
Carbon Dioxide (CO2) transmitter for room mounting, IP41, with Temperature and Humidity options,CO2 output 0-10 VdcTEMP. output 0-10 VdcHUM. output 0-10 VdcModbus RS485 communication, LCD Display, 2 x relay outputs and Buzzer
Part Number: CO2R C1T1H1 MDR2B
$494.00 ex GST